West 13 mm Swabable Vial Adapter. Vial adapters are a cost-effective solution for the safe and rapid transfer and reconstitution of drugs between vials and syringes. Vial adapter spike technology provides a reproducible engineered depth.
Shop online products under categories of Baby, Toys, Sports, Electronics, Beauty & Grooming, Home & Kitchen, Health, Fashion, Books, etc. on Desertcart in El Salvador
Small vial adapter with vented Material Filter (PALL) ABS PP (cap) Can help the medical staff avoid drug infection. (See in Pic 3) And we can glue Gen2 needleless connector on it. Or assemble the CA-016 on it. (See in Pic 2) Picture location
· 10. Place the vial adapter over the Ixinity vial on the table firmly push the filter spike of the vial adapter through the center of the Ixinity vial rubber circle until the clear plastic cap snaps onto the Ixinity vial. 11. Slowly push the plunger rod down to transfer all of the liquid from the syringe into the Ixinity vial.
· – 1 vial adapter, with an integrated particle filter with a pore size of 25 micrometer. Vial Type I glass vial closed with a chlorobutyl rubber stopper, covered with an aluminium cap. The closed vial is equipped with a polypropylene tamper-evident snap-off cap.
Description. Helapet are pleased to offer the 20mm Swabable Vial Adapter, designed to grant safe, easy transfer and reconstitution of drugs from any standard 20mm vial. Presented with a Halkey Roberts ® luer compatible connector, the Swabable Vial Adapter maintains the sterile integrity of the contents during repeated vial access.
· The enhanced inline vent filter allows quick and efficient equalisation of sterile air in the vial for improved flow rates and effortless withdrawal. Providing stable, needle-free access to standard 13mm and 20mm drug vials, the Helapet Vented Vial Adapter range supports safe and precise drug reconstitution, whilst preventing exposure to
· 3. Place product vial on a firm, non-skid surface. Peel off the paper cover on the Vial Adapter plastic housing. Do not remove the adapter from the plastic housing. Holding the adapter housing, place over the product vial and firmly press down (B). The adapter will snap over the vial cap. Do not remove the adapter housing at this step.
· Vented vial access devices can be used on a variety of vials. They feature a .2 micron filter that minimizes aerosols and surface contamination while neutralizing vial pressure. Non-vented vial access devices are a great choice for use on small, low volume vials. Vented vial access devices available in universal, 13mm, 20mm, and 28mm sizes.
· The vial adapter 32 includes a filter cover 49 for deployment between the top cover 43 and the top skirt wall 36. The filter cover 49 encloses an air filter 51 placed on the radial ribs 39. The air filter 51 has a central air filter aperture 52 co-axial with the longitudinal device axis 31.
Lift the packaging off the vial adapter with a vertical movement. Step 3. Remove the cap from the syringe prefilled with diluent solution and screw the syringe onto the vial adapter. Slowly push the plunger all the way down to transfer all the diluent solution in the vial. Step 4.
· The filter media allows the passage of air to the atmosphere outside the vial for pressure equalization. In another aspect, a third filter medium is used in the vent of the adapter to allow gas to pass in either direction through it, but prevents bacteria and particulate matter in the atmosphere from reaching the second filter device.
Vented Vial Access Adapter, PIN13, PIN20, PIN28. 99.99% protection against aerosols and vapors. Low residual. Multi-use with drip- free connector. Vented with dual pathway non-coring plastic spike and pressure equalization with 0.2 micron one way filter.
· combination of syringe filters, syringes, autosampler vials, septa, and caps with a single unit. Easy as 1-2-3 Description Part No. 0.45 μm PTFE filter vial, 100/pack 0.20 μm PTFE filter vial, 100/pack 0.45 μm Nylon filter vial, 100/pack 0.20 μm Nylon filter vial, 100/pack 0.45 μm RC filter vial, 100
This vial an O-ring in the cap that makes it absolutely leakproof like other storage vials this vial can also be used for storage purpose.
Vial adapters are a cost-effective solution for the safe and rapid transfer and reconstitution of drugs between vials and syringes. Vial adapter spike technology provides a reproducible engineered depth. for drug and diluent aspiration, which greatly reduces the end-user variability associated with traditional needle aspirations and helps
· 10. Place the vial adapter over the Ixinity vial on the table firmly push the filter spike of the vial adapter through the center of the Ixinity vial rubber circle until the clear plastic cap snaps onto the Ixinity vial. 11. Slowly push the plunger rod down to transfer all of the liquid from the syringe into the Ixinity vial.
APC custom air filters can be designed to meet airflow ranges from 1 to 5000 SCFM with efficiencies ranging from 60 to 99.999995% at 0.3 microns including MERV filter ratings from 11 to 15. Virtually any filter shape can be made including heptagon, decagon, hexagon, pentagon, nonagon and triangle. > View our OEM Air Filter capabilities.
A vented vial adapter has a filter attached to a vent arm that includes at least two filter media for suppressing aerosolized medicaments from leaving the vial and suppressing bacteria and other contaminants from entering the vial during reconstitution activities of the medication in the vial. The filter media allows the passage of air to the atmosphere outside the vial for pressure equalization.
Amber glass injectable antibiotic vial, 20ISO/DIN neck finish Personalised advice, 4500 references, volume discount, dispatch within 48 hours! 🚚 🕐
· A vented vial adapter has a filter attached to a vent arm that includes a t least two filter media for suppressing aerosolized medicaments from leavin g the vial and suppressing bacteria and other contaminants from entering the vial during reconstitution activities of the medication in the vial.
Vial Adapter Codan US Corporation C350N. Call Us. Medical professionals, medical facility employees 855.571.2100. Need help with SupplyManager?
· 11. Withdraw solution into the syringe by holding the vial on end above the vial adapter and syringe (I) then draw the plunger rod out slowly and smoothly. Ensure that the entire content of the vial is drawn into the syringe. 12. With the plunger rod in place, remove the syringe from the vial adapter (the latter should remain attached to the vial).
The BD PhaSeal ™ drug vial access device permanently affixes to a drug vial. It functions as a pressure equalization device, utilizing a sealed expansion chamber that establishes and maintains neutral pressure when air or diluent is injected into or aspirated from the vial.
One variant of the vial adapter is integrated with a filter to address various types of particles. In the present study, the performance of the filter-integrated vial adapter is evaluated with respect to glass delamination particles. Silica particles of 0.5–10 μm are used to emulate glass delamination particles.
C350N Vial Adapter Dispensing Pin Case 50. Login to see prices & order. Compare. Compare This Product. CODAN Spike with 0.2 micron air eliminating filter, SWAN-LOCK® NeedleFree Adapter. Spike with 0.2 μ Air Eliminating Filter, Needle-Free. Manufacturer # C350N. Manufacturer Codan US Corporation. Application Vial Adapter.
Product Number. Product Description. SDS. TZHASV210. suitable for sterility testing, with small diameter double needle adapter for liquids in small vials with septa, mixed cellulose esters (MCE) (for membrane filter), pkg of 10 blisters per box, Single packed.
Prepare Shell Vial. Add Dispersive Salts (MgSO4) and/or Column Sorbents (C-18) Add Homonegized Sample. Add Solvent/Buffer & Water to bring up to volume. Vortex. Depress Plunger completely to filter. Prepared clean samples are now ready for LC/MS with separated salts, sorbents & sample debris.